Flanged swing configuration
Check hinge orientation, cover access and closure behavior with the actual flow and system shutdown.
Compare flanged swing and lift check valves by connection fit, flow range, opening differential and shutoff requirements.
Request a quote

Check hinge orientation, cover access and closure behavior with the actual flow and system shutdown.

Confirm guided travel, opening differential, permitted mounting orientation and pressure loss at the expected duty.
A flanged check valve connects to the line through bolted end flanges and limits reverse flow using a self-acting closure. Choose the swing or lift construction according to the operating flow, allowable pressure drop and mounting position. For the connection, record the actual flange specification, rating designation, facing and bolt pattern at both ends. End flanges define the piping interface. Opening and closure depend on the offered mechanism and process conditions.
For a spare or retrofit, send the existing valve tag, installed length and photos of the mating flange faces. Compare face-to-face length with the offered drawing. Mark the forward flow direction and whether the line is horizontal or vertical. If the valve is near a pump, note nearby elbows or reducers and the shutdown sequence. Ask for model-specific mounting instructions, pressure loss and review of the operating flow range.
| Item | Send with your inquiry | Check on the offer |
|---|---|---|
| Connections | Flange standard and rating, facing and installed length | Mating flange compatibility and dimensioned outline |
| Operating flow | Minimum, normal and maximum flow and allowable operating loss | Flow range and pressure loss at relevant points |
| Mounting | Pipe axis, forward direction and adjacent piping | Permitted orientation and any clearance or access requirements |
| Acceptance | Closed differential, service medium and required leakage criteria | Pressure and temperature limits and the specified test scope |
Separate dimensional and functional review on the quotation. If the project specifies ASME dimensions, B16.5 and B16.10 cover different subjects within their scopes, namely the flange interface and valve installation dimensions. Check the project edition and applicable tables against the actual offered drawing. Ask the supplier to document the closure design and service limits independently of the flange designation.
Review the selection question and confirm the offered drawing, materials and requirements with your inquiry team.
Check flange drilling and facing, then compare the distance between the flange faces and available body clearance. Review the orientation, flow direction and closure requirements for the offered model. A replacement with matching ends still needs to be reviewed for pressure loss, stable opening and shutdown behavior in the existing line.
Compare the two designs using the expected flow range, pressure-drop limits, valve orientation and shutdown conditions. A hinge and guided closure respond differently to changes in flow. Request operating information for the actual valve and check the fit and access before ordering.
Specify vertical upward or downward flow explicitly on the drawing. Verify the specific valve's allowed orientation and guide, spring or hinge arrangements. Confirm the forward arrow during installation and check the operating differential for stable opening.
Provide the pump flow range and intended operating sequence, including shutdown and any parallel pumps on a shared header. Send the pipeline layout with valve location and available length. Note whether pressure surges or reverse flow have been observed and share relevant pressure data.
Ask for loss at the actual flow points and operating conditions. Obtain the minimum recommended flow for stable operation and the opening differential if relevant. Compare suppliers using the same fluid, orientation and operating basis.
Send the required size, process duty, installation dimensions and quantity.