Electric quarter-turn operator reference
Use the required duty, torque and controls to identify the proposed electric operator and accessories.
Specify an electric butterfly valve for remote isolation or positioning. Match the operator duty, available power and disc torque before deciding which valve body, seat and controls to quote.
Request a quote

Use the required duty, torque and controls to identify the proposed electric operator and accessories.

Use the valve body layout to review flange and disc fit. Confirm the electric assembly dimensions and mounting separately.
Begin with the valve torque through its stroke. Send the differential at opening and closing, process fluid, seat material, temperature and periods of inactivity. Ask for the torque basis, output margin and limits on shaft loading. For on-off duty, state the permitted opening and closing times and how often the valve cycles. If frequent positioning is required, give the travel pattern and starts per hour. Confirm that the actuator duty and the valve flow characteristics both suit the intended use.
List site voltage, phase and frequency or the DC supply available at the valve. Specify how the control system commands movement and what status it needs back. If loss of command signal and loss of power require different actions, document both cases. Include the allowable closing time where surge is a concern. For installation, check the assembled height, cable entry, manual override and space for actuator removal. Compare the full disc envelope with the pipe bore and any lining or close fittings.
| Item | Send with your inquiry | Check on the offer |
|---|---|---|
| Torque | Differential, temperature, seat and service conditions | Valve torque basis, operator output and shaft limits |
| Duty and time | Normal cycles, starts per hour and allowed stroke time | Duty rating, timing and operating limitations |
| Electrical scope | Supply, commands, indication and failure states | Wiring, terminals, control options and proposed response |
| Installed fit | Flanges, disc space, cable route and access | Assembly drawing, support and service envelope |
Send Val-Man the piping datasheet and controls requirements using the same valve tag. If the order is for a replacement, include the old assembly drawing and state what must change. Ask for the valve, actuator, mounting kit and accessories to be listed with the drawing and wiring documents.
Review the selection question and confirm the offered drawing, materials and requirements with your inquiry team.
Check the operating range and expected positioning frequency. Ask for valve flow data versus disc position and the actuator duty at the required loads. Specify the position command, feedback and acceptable response so the offered package can be checked against the control loop.
Specify whether the valve should close, open or stay in position during loss of power. If movement is required, ask for the proposed energy source or fail mechanism and confirm it will complete the stroke at the specified differential. Review loss of command signal separately.
Provide the original valve tag, mounting interface, shaft details and existing operator drawings. Ask for the proposed coupling and bracket arrangement. Verify torque, full disc travel, position indication and access for override before accepting the conversion.
Give the system designer the flow conditions, pipe arrangement and desired sequence. Include the approved closing-time range on the inquiry and ask how the proposed assembly will be checked. Verify the time from fully open to closed under the stated load and supply.
Request the wiring diagram, terminal details, actuator rating and configuration, along with the included position indication and interlocks. Give the enclosure and ambient conditions. If the installation calls for area approval, specify it and ask for evidence for the exact model.
Send the required size, process duty, installation dimensions and quantity.